Transmittance Measurement

What Is Transmittance Measurement?

Transmittance measurement refers to the quantitative determination of how much light or electromagnetic radiation passes through a specific medium or material. Expressed as a ratio or percentage, transmittance represents the fraction of incident light that successfully traverses a sample without being absorbed, reflected, or scattered. This optical property evaluation provides critical information about a material’s transparency, optical density, and composition.

In its most fundamental form, transmittance (T) is calculated as:

T = I/I₀

Where:

  • I represents the intensity of light after passing through the sample
  • I₀ represents the initial intensity of the incident light

When expressed as a percentage, this value ranges from 0% (complete opacity where no light passes through) to 100% (perfect transparency where all light passes through). The complementary property to transmittance is absorptance, which quantifies the light retained within the material rather than passing through it.

How to Measure Transmittance – Methods and Techniques

Scientists and engineers measure transmittance using various techniques depending on the specific application requirements, material properties, and desired precision. The selection of an appropriate method is critical for obtaining reliable and reproducible results.

Spectrophotometry

The most common technique for optical analysis involves spectrophotometers – precision instruments that evaluate how materials interact with light across various wavelengths. Modern spectrophotometers can operate across ultraviolet, visible, and infrared regions of the electromagnetic spectrum.

The basic operating principle includes:

  1. A light source generates radiation at specific wavelengths
  2. The light passes through the sample
  3. A detector captures and analyses the transmitted light
  4. Software calculates the transmittance ratio and displays results

Integrating Sphere Methods

For materials with significant light scattering properties, integrating spheres provide enhanced accuracy. These hollow spherical chambers have interior surfaces coated with highly reflective materials that collect scattered light, ensuring more comprehensive detection and analysis. Measuring transmittance of diffuse materials requires these specialised systems to account for scattered light that standard detectors might miss.

Laser-Based Systems

For applications requiring extreme precision or measurement at specific wavelengths, laser-based systems offer good performance. By utilising monochromatic laser light sources, these setups can detect minute variations in transmission properties accurately. Because they operate at specific wavelengths, these systems are less suitable for applications requiring wide spectral coverage (e.g., multispectral or hyperspectral imaging).

Inline Process Monitoring

Industrial applications often require continuous evaluation of optical properties during manufacturing. Specialised inline systems incorporate transmittance sensors directly into production lines, allowing real-time monitoring without disrupting workflows.

Applications of Transmittance Measurement in Different Industries

Pharmaceutical Quality Control

In pharmaceutical manufacturing, light transmission analysis ensures product consistency and purity. Solutions and suspensions undergo regular testing to verify concentration, detect contaminants, and confirm formulation accuracy. For injectable medications, transmittance testing represents a critical safety verification step. Living Optics’ advanced hyperspectral imaging systems make it possible for pharmaceutical researchers to analyse variations in drug formulations, which can improve quality assurance throughout the production process and beyond the primary manufacturing plant to the entire supply chain.

Materials Science and Development

Engineers and scientists utilise transmission data to characterize new materials, optimise formulations, and predict performance characteristics. For technologies incorporating optical components – from solar panels to protective coatings – understanding light interaction properties proves essential for effective design and implementation. Living Optics has revolutionised this field with their high-resolution spectral scanning technology, allowing researchers to observe subtle transmittance variations across multiple wavelengths simultaneously, dramatically accelerating material development cycles.

Environmental Monitoring

Water quality assessment frequently relies on light transmission techniques. Turbidity measurements – essentially inverse transmittance evaluations – provide rapid indications of suspended particle content in water supplies. Environmental scientists using hyper-spectral analysis tools can conduct comprehensive water quality assessments in remote locations with laboratory-grade precision, detecting contaminants at previously unmeasurable concentrations. The same technology has been successfully applied to measure plant health in laboratory settings, providing researchers with detailed spectral data to monitor crop conditions and stress responses non-invasively.

Food and Beverage Industry

Quality assurance in food production utilises optical transmittance measurement to verify clarity in liquids like oils, juices, and alcoholic beverages. Automated imaging systems can be integrated into production lines to provide compositional analysis through transmittance variations, enabling food processors to identify subtle quality deviations before they become visible to the human eye.

Automotive and Transportation

Glass and transparent polymer components undergo rigorous transmittance testing to ensure optimal visibility and safety. The automotive industry can leverage Living Optics’ multi-wavelength spectral technology to optimise both safety and aesthetic qualities of next-generation transparent components, ensuring precise light management across the entire visible spectrum and beyond.

Factors Affecting Accurate Transmittance Measurement

Sample Preparation Considerations

Reliable results demand meticulous sample handling procedures. Fingerprints, dust particles, or minor scratches on sample surfaces can significantly distort readings. Proper cleaning protocols, appropriate containment vessels, and consistent sample positioning all contribute to measurement precision.

Instrument Calibration

Accuracy depends fundamentally on proper instrument calibration. Regular verification against certified reference materials ensures reliable results. Modern systems typically require both baseline calibrations (0% transmittance, achieved by blocking all light) and 100% transmittance standards.

Environmental Variables

Temperature fluctuations can alter material properties and instrument performance. Similarly, humidity variations may affect certain sample types or introduce condensation on optical surfaces. Controlled laboratory environments provide the most consistent results.

Wavelength Considerations

Transmittance varies significantly across different wavelengths. Complete characterisation often requires measurements across the entire spectrum of interest, as materials may exhibit transparency in certain regions while blocking others. Accurate optical transmittance measurement requires selecting appropriate wavelength ranges for the specific material being analysed.

Frequently Asked Questions

How does transmittance differ from transparency?

While often used interchangeably in casual contexts, transmittance represents a precise quantitative measurement, whereas transparency describes the qualitative visual perception of how clearly objects can be seen through a material.

What’s the relationship between transmittance and absorbance?

These complementary properties relate logarithmically. While transmittance measures the light passing through a sample, absorbance quantifies light retention. Mathematically: Absorbance = -log₁₀(Transmittance).

Can transmittance exceed 100%?

In standard definitions, transmittance cannot exceed 100%, as this would indicate creating light rather than merely passing it. However, certain optical phenomena like fluorescence may cause apparent readings above 100% when emission occurs at the measured wavelength.

We would love
to hear from you